Ultra-Thin Airflow Wall
The ultra-thin airflow wall is a high-efficiency, energy-saving cooling solution designed for medium to large data centers. The unit adopts a chilled-water cooling system (optional refrigerant or dual cooling sources). The chilled-water version supports high supply water temperatures and, during low-temperature seasons, can operate with chillers to achieve free cooling, extending the annual utilization of natural cooling sources and enabling precise temperature and humidity control. Designed for short-distance air delivery and space-constrained environments, the ultra-thin airflow wall offers a cooling capacity ranging from 150 to 300 kW. Its cooling system is closely integrated with the data center infrastructure, utilizing the building structure for long-distance air supply and return without the need for raised floors, resulting in enhanced cooling performance and improved space efficiency.
Product Features:
◆Extra-large, low-resistance coil design supports higher water temperatures and reduces energy consumption.
◆Matrix-style airflow with horizontal air supply ensures uniform temperature distribution and minimizes turbulence.
◆Enclosed airflow channels with hot aisle containment stabilize cold aisles and ensure consistent supply air temperature.
◆Modular control and fan drive design supports hot-swappable modules for faster and easier maintenance.
◆Rapid deployment without raised flooring, reducing cooling system costs by up to 10%.
◆Simple and efficient maintenance with streamlined operation.
◆Ultra-thin, lightweight design improves data center space utilization.
ULTRA-THIN AIRFLOW WALL TECHNICAL SPECIFICATION:
|
Model |
FWAH100C-UT |
FWAH200C-UT |
FWAH300C-UT |
|
Power |
220VAC 50/60HZ |
||
|
Inlet Temperature: – °C |
15 |
15 |
15 |
|
Outlet Temperature: – °C |
21 |
21 |
21 |
|
Return Air Temperature: – °C |
35 |
35 |
35 |
|
Total Cooling Capacity: – kW (TR) |
100(28) |
200(57) |
300(85) |
|
Sensible Cooling Capacity: – kW |
100 |
200 |
300 |
|
Full Load Current (FLA-A) |
25 |
55 |
80 |
|
Rated Water Flow Rate: – m³/h |
14.5 |
29 |
43.5 |
|
Water Pressure Drop: – kPa |
80 |
80 |
80 |
|
Airflow Rate: – m³/h (CFM) |
24000 |
48000 |
72000 |
|
Number of EC Fans |
6 |
12 |
18 |
|
External Static Pressure: – Pa |
50 |
50 |
50 |
|
Inlet Pipe Diameter: – mm |
DN50 |
DN65 |
DN80 |
|
Outlet Pipe Diameter: – mm |
DN50 |
DN65 |
DN80 |
|
Length: – mm |
1500 |
3000 |
4500 |
|
Depth: – mm |
400 |
400 |
400 |
|
Height: – mm |
2200 |
2200 |
2200 |