Home > Server Cooling Systems > Server Cooling Solutions > Server cooling solutions
●Optional configuration – fit your specific requirement
●Energy efficient – high efficiency fan and compressor
●Smart Control – a new microcomputer controller
●Multi module – can realize mutual linkage
●Reliable and high quality cooling system
●Easy installation
●Lifetime over 10 years – minimum maintenance
Why produced raw-based air conditioners?
The heavy load in computer applications is mainly caused by the increasing loads of data center racks and it finally produces heat load density which is relatively high. Because of unpredictable heavy loads, the remarkable performance of cooling system is required, at the same time occupies small space, so as provides more space for equipment in the room.
The raw-based air conditioner has the advantage of energy saving in the market of air conditioner because the space is the same as the value.
Where are raw-based air conditioners applied?
RA Lines
Models | RA10-A5S | RA20-A5S | RA22-A5SV | RA30-A5S | RA40-A5S | RA40-A5SV | |
---|---|---|---|---|---|---|---|
Cooling Capacity (37℃DB/24%RH) |
Kw | 10.2 | 20.4 | 22 | 30.2 | 40.5 | 40 |
Sensible cooling Capacity (37℃DB/24%RH) |
kw | 10.2 | 20.4 | 22 | 30.2 | 40.5 | 40 |
Cooling Capacity (30℃DB/34%RH) |
kw | 9.3 | 18.5 | 19 | 27.2 | 35.5 | 35 |
Sensible cooling Capacity (30℃DB/34%RH) |
kw | 9.3 | 18.5 | 19 | 27.2 | 35.5 | 35 |
Power consumption | kw | 2.8 | 5.9 | 5 | 9.4 | 11.2 | 9.1 |
Internal Airflow | m3/h | 3000 | 4200 | 5000 | 6000 | 8400 | 8000 |
Main module dimensions (H×W×D) | mm | 2000×300×1080 | 2000×300×1080 | 2000×300×1080 | 2000×600×1200 | 2000×600×1200 | 2000×600×1200 |
Main module weight | Kg | 158 | 196 | 200 | 274 | 320 | 330 |
Mount Method | side mount | side mount | side mount | side mount | side mount | side mount | |
Cooling module dimensions (H×W×D) | mm | 850×1040×822 | 960×1240×1178 | 1565×1000×800 | 960×2140×873 | 960×2140×1076 | 1565×1800×800 |
Cooling module weight | Kg | 46 | 79 | 140 | 120 | 148 | 280 |
RW Lines
Models | RW10-A5S | RW20-A5S | RW22-A5SV | RW30-A5S | RW40-A5S | RW40-A5SV | |
---|---|---|---|---|---|---|---|
Cooling Capacity (37℃DB/24%RH) | kw | 10.2 | 20.4 | 22 | 30.2 | 40.5 | 40 |
Sensible cooling Capacity (37℃DB/24%RH) | kw | 10.2 | 20.4 | 22 | 30.2 | 40.5 | 40 |
Cooling Capacity (30℃DB/34%RH) | kw | 9.3 | 18.5 | 19 | 27.2 | 35.5 | 35 |
Sensible cooling Capacity (30℃DB/34%RH) | kw | 9.3 | 18.5 | 19 | 27.2 | 35.5 | 35 |
Power consumption | kw | 2.4 | 4.8 | 5 | 7.9 | 9.8 | 9.1 |
Internal Airflow | m3/h | 3000 | 4200 | 5000 | 6000 | 8400 | 8000 |
Main module dimensions(H×W×D) | mm | 2000×300×1080 | 2000×300×1080 | 2000×300×1080 | 2000×600×1200 | 2000×600×1200 | 2000×600×1200 |
Main module weight | Kg | 158 | 196 | 200 | 274 | 320 | 330 |
Mount Method | side mount | side mount | side mount | side mount | side mount | side mount |
CW Lines
Models | CW24-A5S | CW31-A5S | CW40-A5S | CW50-A5S | CW65-A5S | |
---|---|---|---|---|---|---|
Inlet/outlet water temperature | ℃ | 7/12 | 7/12 | 7/12 | 7/12 | 7/12 |
Water flux | m3/h | 4.5 | 5.4 | 6.9 | 8.6 | 11.3 |
Cooling Capacity (37℃DB/24%RH) | kw | 24 | 31 | 40 | 50 | 65.5 |
Sensible cooling Capacity (37℃DB/24%RH) | kw | 24 | 31 | 40 | 50 | 65.5 |
Cooling Capacity (30℃DB/34%RH) |
kw | 21.5 | 27.7 | 35.8 | 44.7 | 58.6 |
Sensible cooling Capacity (30℃DB/34%RH) | kw | 21.5 | 27.7 | 35.8 | 44.7 | 58.6 |
Power consumption | kw | 1.05 | 1.1 | 1.55 | 1.8 | 2.7 |
Pressure drop | kPa | 59 | 61 | 67 | 75 | 87 |
Internal Airflow | m3/h | 4500 | 4800 | 6000 | 8400 | 12000 |
Main module dimensions (H×W×D) | mm | 2000×300×1080 | 2000×300×1080 | 2000×600×1080 | 2000×600×1080 | 2000×600×1080 |
Main module weight | Kg | 165 | 175 | 253 | 275 | 288 |
Mount Method | side mount | side mount | side mount | side mount | side mount |